Electrical Design
Winding
All crane duty motors are manufactured using dual coat class F copper wire (with temperature withstand up to 1550C) as standard.
Insulation
The motors are having class F insulation with temperature rise limited to Class B. The motors are impregnated in a computerized impregnation plant that ensures high quality of impregnation with high varnish retention.
Deration for Higher Ambient & Altitude
For selection of motors for higher ambient and altitude, the rated kW should be reduced by the following factors for the frame selection.
Ambient 450C 500C 550C 600CFactor 100% 95% 90% 80%Altitude 1000m 1500m 2000m 2500m 3000mFactor 100% 95% 92% 88% 84%
Intermittent Duty Application
The motors are designed for intermittent duty operations and different starts/stops per hour as shown in the rating charts. The frame selections are based considering load GD2 values referred to motor shaft are less than or equal to motor GD2 values. Various intermittent duty types are explained below.
Short Time Duty - S2 Duty
The motor operates at constant load for a given duration which is less than that required to reach thermal equilibrium and is followed by a rest or de-energized period such that the motor cools down to close to ambient temperature.
The recommended values for the short time duty are 10, 30, 60 and 90 minutes.
Intermittent Periodic Duty with Starting- S3 Duty
The operation cycle consists of operation at constant load followed by a rest and de-energized period. The duty cycle is such that thermal equilibrium is not reached during one periodic cycle. |